|
Project |
Technical Parameters |
|
Table body accuracy level |
0.1 level |
|
Device standard table configuration |
HS-5100 single-phase multi-function standard meter, accuracy grade: 0.05; |
|
The output voltage |
Range: 220V, adjustment range: 0-120%, adjustment fineness: 0.01% full scale; |
|
Output current |
10mA-50A (100A optional), adjustment fineness: 0.0001A (minimum); |
|
Output phase |
Range: 0-359.99°, adjustment fineness: 0.01°; |
|
Output frequency |
45Hz-65Hz, adjustment fineness: 0.01 Hz; |
|
Output waveform distortion |
Voltage and current: ≤0.5%; |
|
Power stability |
≤ 0.05%; |
|
Load characteristics |
Resistive, inductive, capacitive |
|
Start current output |
1mA (minimum), accuracy: 2%, starting power: accuracy 5%; |
|
Test function |
Basic error test; creep test; start test; standard deviation test; image recognition |
|
Communication test |
RS485 communication test, according to the communication protocol of the tested meter; |
|
Device input power |
Single-phase 220V±10%, 50Hz; maximum power consumption: 1500VA (12 epitopes) |
Dimensions:
|
Integrated |
gauge |
Dimensions: length × width × height mm |
Split |
gauge |
Dimensions: length × width × height mm |
|
6 |
1800×800×1800 |
12 |
1200×800×1800 |
||
|
12 |
1800×800×1800 |
Cabinet |
600 (width) × 800 (depth) × 1800 (height) |

English
中文简体


-->