Product

return
  • HS-6321 three-phase electric energy meter withstand voltage test device
  • HS-6321 three-phase electric energy meter withstand voltage test device

HS-6321 three-phase electric energy meter withstand voltage test device

It is applicable to the measurement and test centers of power companies in various provinces (cities, districts), the measurement departments of power supply companies, and electric energy meter manufacturers.
This device is used to verify the withstand voltage of various induction three-phase electric energy meters, electronic three-phase electric energy meters, three-phase prepaid electric energy meters, three-phase multi-function electric energy meters, three-phase smart electric energy meters, etc. test.

share:

Phone : 0086-573-86161698

contact us

Description

Project

HS-6321

HS-6321B

Pressure tester

Voltage setting

200~5kV AC, manual

200~5kV AC, manual and automatic mode

Maximum output power

500VA(100mA@5.000kV)

500VA(100mA@5.000kV)

Output waveform

Sine wave, distortion degree: ≦5%

Sine wave, distortion degree: ≦5%

Output frequency

50Hz or 60Hz

50Hz or 60Hz

Leakage current

0.1~100mA, accuracy: ±5%

0.1~100mA, accuracy: ±5%

Leakage current detector

Test Range

0.5~10mA

0.5~10mA

Resolution

0.01mA

0.01mA

Precision

±5%

±5%

communication

no

Have

Time range of withstand voltage test

1~99 seconds

Number of device meters

8, 16 epitopes are optional, and can also be customized according to customer requirements.

Power supply

AC 220±10%, 50/60Hz, maximum power consumption: 1000VA (16 meters)

working environment

Temperature: 20℃±5℃; Humidity: <85% RH

Functional advantage:
Can carry out the withstand voltage test on the three-phase electric energy meter separately, and the test process is automated
The output voltage value and leakage current protection value can be set manually or through a PC
Set up an emergency stop button to quickly cut off the power supply and abort the test
Set up sound and light alarm device to remind the operator in time when there is a non-conforming list
Equipped with a protection device, when a person approaches the high-voltage area by mistake, the high-voltage test automatically stops

Function configuration table:

Device model

HS-6321

HS-6321B

Withstand voltage meter

Manual

Program control

Leakage current detector

HS-1013

HS-1013B (with RS-485 communication interface)

Types of withstand voltage test

●Voltage and current vs. shell ●Voltage vs. current

Note: ●─Basic configuration; 〇─Optional configuration

 

Dimensions (unit: mm):

Integrated

Split

gauge

Table stand

Dimensions: length × width × height

gauge

Table stand

Dimensions: length × width × height

8

1

2200×800×1600

8

1

2200×800×1600

16

1

2200×800×1920

16

1

2200×800×1920

Cabinet

600 (width) × 800 (depth) × 1845 (height)

Contact us

Drop us a line or give us a ring. We love to hear from you and are happy to answer any questions

Request a Quote