Product

return
  • HS-6103 Single phase energy meter test bench
  • HS-6103 Single phase energy meter test bench

HS-6103 Single phase energy meter test bench

HS-6103 single phase energy meter test bench adopts SPWM digital amplify technology, equips with high accuracy digital reference standard meter, multi-path voltage transformer, to realize multi-positions error testing.

share:

Phone : 0086-573-86161698

contact us

Description

Items

0.03 class

0.05 class

0.1 class

Accuracy of reference standard meter

HS-5100H/0.02

HS-5100/0.05

HS-5100/0.1

Output range

voltage:30 ~ 300V

current:1mA ~ 120A

voltage:30 ~ 300V

current:1mA ~ 120A(200A optional)

Phase angle

0~360 °,resolution:0.01°

Frequency

45 ~ 65Hz ,resolution:0.01Hz

Waveform distortion

voltage、current< 0.5%(liner load)

Power stability

< 0.02%/120 s  

< 0.05%/120 s

Output range

voltage:200VA(6positions)

current:250VA(100A)

voltage:400VA(24 positions)current: 900VA(100A)

Max load can rise to 2000VA for current with the increase of the position number, voltage 1200VA

Load characteristic

resistive, inductive, capacitive(less than 1uF/ each position, the Max. is less than 48 uF)

Starting current output

Min. 1mA, accuracy: ≤ 2%,starting power: accuracy≤ 2%

Communication test

RS485/232/ infrared / carrier wave, support DL/T645-1997/2007、698.45、IEC1107

Environment condition

Temp.:20℃ ±5℃;Humidity:< 85% R.H.

Power supply

AC 220±10%,50/60Hz,AC120/240V(optional);

Max. consumption:1500VA(24 positions)

Dimensions(unit:mm, position recommendation)

Integration

Fission

position

rack

size: L×W×H(mm)

position

rack

size: L×W×H(mm)

6

1

1600×750×1600

12

1

1600×700×1920

1600×800×1100(horizontal)

24

1

2200×700×1920

12

1

1600×750×1920

48

2

2200×700×1920

24

1

2200×750×1920

60

2

2000×700×1920

48

2

2200×750×1920

cabinet

600×800×1920(mm)

Function Parameters:

Items

HS-6103

HS-6103B

HS-6103C

HS-6103E

HS-6103F

HS-6103G

HS-6103H

Basic functions

basic error

creeping test

starting test

standard deviation

Constant test

dial test

influence test

 

 

Multi-functions test

 

daily timing error☆

 

 

period switching

 

 

energy display error

 

 

Register checking

 

 

GPS timing☆

 

 

communication test☆

 

 

State grid test

consistency test

 

 

 

Com. protocol consistency checking

 

 

 

event record

 

 

 

charge test☆

 

 

 

power consumption  test☆

 

 

 

Contact us

Drop us a line or give us a ring. We love to hear from you and are happy to answer any questions

Request a Quote

5,400