Product

return
  • HS-6103M/HS-6303M MCM smart meter test bench
  • HS-6103M/HS-6303M MCM smart meter test bench
  • HS-6103M/HS-6303M MCM smart meter test bench
  • HS-6103M/HS-6303M MCM smart meter test bench

HS-6103M/HS-6303M MCM smart meter test bench

These serial products are designed based on IR46 standard and MCM smart meter requirement. They meet the IR46 requirement of harmonic and small current and support IR46 relevant evaluation.

The devices have PC control program, can provide complete solution for energy meter automatic testing. At the meantime, DLL is provided to users for their own program development, it improves users’ self-control and management ability.

share:

Phone : 0086-573-86161698

contact us

Description

Item

Technical Para.

Model

HS-6103M single phase MCM smart meter test bench

Accuracy of test bench

0.1

0.05

0.02

Reference standard meter

HS-5100B single phase multifunction reference standard meter

0.05 class

0.02 class

Voltage range

0-240V ;0-120%, fineness: 0.01% full scale;

Current range

0.1mA-100A  fineness: 0.0001A(Min.)

Phase angle

range:0-359.99°; fineness:0.01°

Frequency

45Hz-65Hz ; fineness:0.01 Hz

Distortion

voltage,current < 0.5%;

Power stability

≤ 0.1%

≤ 0.05%

≤ 0.02%

Load characteristic

resistive, inductive and capacitive

Harmonic output

harmonic:2~99,Up to 10 harmonic overlays can be performed;

content: less than 40%(compare to fundamental wave);

harmonic phase angle: 0°~359.99°

angle better than 1°

accuracy better than 2%(content>1%)

Starting current output

0.1mA (Min.) ,accuracy: 1%, starting power: accuracy1%

Communication test

RS485,or according to protocol of energy meter

Position

24 positions、48positions(standard);or custom made

Power supply

AC220V±10%,50Hz/60Hz,(AC120V/240V optional)

Max. consumption:1500VA(take 24 positions as example)

Dimension

integration(L×W×H mm)

fission(L×W×H mm)

24 positions:2400×750×1920

24 positions:2400×750×1920

48 positions:2400×750×1920 × 2

48 positions:2400×750×1920 × 2

 

cabinet:600×800×1920



Items

Technical

Model

HS-6303M three phase MCM smart meter test bench

Accuracy of test bench

0.05

0.02

Reference standard meter

HS-5300B three phase multifunction reference standard meter

0.05class

0.02class

Voltage range

3×30-480V ;0-120% fineness: 0.01% full scale, adjust phase by phase

Current range

3×0.1mA-100A fineness: 0.0001A(Min.) ,adjust phase by phase

Phase angle

range:0-359.99°; fineness:0.01°,adjust phase by phase

Frequency

45Hz-65Hz ; fineness:0.01 Hz

Distortion

voltage, current  < 0.5%;

Power stability

≤ 0.05%

≤ 0.02%

Load characteristic

resistive, inductive and capacitive

Harmonic output

harmonic:2~99, Up to 10 harmonic overlays can be performed

content: less than 40%(compare to fundamental wave);

phase angle:0°~359.99°

Angle better that 1°

Accuracy better than 2%(content>1%)

Starting current output

0.1mA (Min.) ,accuracy:1%,starting power: accuracy 1%

Communication test

RS485, or according to protocol of energy meter

Position

16 positions、32positions(standard);or custom made

Power supply

AC220V±10%,50Hz ,(AC120V/240V optional)

Max. consumption:5000VA(take 16positions as example)

Dimension

integration(L×W×H mm)

fission(L×W×H mm)

16 positions:2400×800×1920

16 positions: 2400×800×1920

32 positions: 2400×800×1920 × 2

32 positions:2400×800×1920 × 2

 

cabinet:600×800×1920

Function advantage
1.Install 7 inch touch screen, easy operation;
2.Adopt SPWM digital amplify technology, high stability and performance, large power      output;
3.current is 1mA, meet IR46requirement;
4.Output different waves, like sine, harmonic, sub-harmonic, odd harmonic, square wave, peak wave, pulse wave etc. or wave that user defined; up to 50 harmonic can be output, harmonic content is 40%;
5.Support DC even harmonic test;
6.Output variety of energy, full wave energy, fundamental wave energy, harmonic energy output can be selected; also can select harmonic position, harmonic negative, and sub-harmonic energy output;
7.Support 10 kinds of harmonic waveform test of IR46 and IEC, and 7 special voltage drop and interrupt waveforms is added, it can calculate error through the way of long time electric energy accumulation;
8.Support IR 46 and 2020 Version relevant evaluation;
9.Has current rapid change test function;
10.Support neutral current test function;
11.Support Bluetooth pulse, and Bluetooth communication system;
12.Support dual photoelectric sampling, and can do pulse sampling for both state grid and southern grid energy meters;
13.Support error self-monitor function( according to customer require);
14.Support terminals temperature test function(according to customer require).

Contact us

Drop us a line or give us a ring. We love to hear from you and are happy to answer any questions

Request a Quote

5,400

happy clients