HS-6403M-U DC voltage dips and short interruptions test bench is developed based on IR46 standard and start grid 20 version electric energy standard, it comply with GB/T17626.29-2006.

share:

Phone : 0086-573-86161698

contact us

Description

Item

Technical Para.

Accuracy of test bench

0.05

Reference standard meter

HS-5300B three phase multifunction standard meter, accuracy :0.05

DC voltage

0-480V , adjust range:0-120% , fineness:0.01%; 

AC voltage

0-240VDC

Current range

0.1mA-120A, fineness:0.0001A(Min.)

Phase angle

Range:0-359.99°;fineness:0.01°

Frequency

45Hz-65Hz ; fineness:0.001 Hz

Distortion

voltage、current≤0.5%;

Load characteristic

resistive, inductive and capacitive

Starting current output

0.1mA (min.) ,accuracy:1%, starting power: accuracy1%;

Communication test

RS485;or according to protocol of energy meter

Position

1 position(standard)

Power supply

AC220V±10%,50Hz ,(AC120V/240V optional)

Max.consumption:500VA

Dimension

cabinet:600×800×1920mm

Function advantage:
1.Install 7 inch touch screen, easy operation
2.DC aux. voltage dips and short interruptions
3.Parameter of voltage dips and short interruptions can be set freely, meet IR 46 latest requirement, minimum dips time is 0.1ms
4.Low consumption Bluetooth system
5.Dual photoelectric sampling